Fading grid on green Commercial Building Ventilation and Indoor Environmental Quality
Home
Research
Publications
References
Staff
Links

References to Publications by Others

Indoor VOCs

ASTM D5116-97
Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products. ASTM International, West Conshohocken, PA.
 
ASTM E981-84
2000. Standard Test Method for Estimating Sensory Irritancy of Airborne Chemicals. ASTM International, West Conshohocken, PA.
 
Girman, J.R., G.E. Hadwen, L.E. Burton, S.E. Womble and J.F. McCarthy
1999. "Individual Volatile Organic Compound Prevalence and Concentrations in 56 Buildings of the Building Assessment Survey and Evaluation (BASE) Study." Proceedings of Indoor Air 1999, The 8th International Conference on Indoor Air Quality and Climate, Edinburgh, Scotland, August 8-13, 1999, Vol. 2, pp. 460-465.
 
Jenkins, P.L, T.J. Phillips, E.J. Mulberg and S.P. Hui
1992. "Activity patterns of Californians: Use of and proximity to indoor pollutant sources." Atmos. Environ. 26A: 2141-2148.
 
Kleno, J.G. and P. Wolkoff
2002. "Eye Irritation from Exposure to PPB Levels of Limonene Oxidation Products." Proceedings of Indoor Air 2002, The 9th International Conference on Indoor Air Quality and Climate, Monterey, CA, June 30-July 5, 2002, Vol. 2, pp. 602-607.
 
Shields, H.C., D.M. Fleischer and C.J. Weschler
1996. "Comparisons among VOCs measured in three types of U.S. commercial buildings with different occupant densities." Indoor Air 6: 2-17.
 
Wolkoff, P., P.A. Clausen, C.K. Wilkins and G.D. Nielsen
2000. "Formation of strong airway irritants in terpene/ozone mixtures." Indoor Air 10: 82-91.
 

Ventilation Rates and Technologies

ANSI/ASHRAE
1997. ASHRAE Standard 129-1997, Measuring Air-Change Effectiveness, to be published by American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc. Atlanta, GA.
 
ASTM D 6245-98
1998. Standard guide for using indoor carbon dioxide concentrations to evaluate indoor air quality and ventilation, American Society for Testing Materials, American West Conshohocken, PA.
 
Björkroth, M., O. Seppänen, and A. Torkki
1998. "Chemical and sensory emissions from HVAC components and ducts", In: Moschandreas, D. (editor) Design, Construction, and Operation of Healthy Buildings - Solutions to Global and Regional Concerns, American Society of Heating, Refrigerating, and Air Conditioning Engineers, Atlanta. pp. 47-55.
 
Committee on the Assessment of Asthma and Indoor Air
2000. Clearing the Air: Asthma and Indoor Air Exposures, Division of Health Promotion and Disease Prevention, Institute of Medicine, Chapter 10. (Online version)
 
Fang, L., G. Clausen, and P.O. Fanger
1998. "Impact of temperature and humidity on the perception of indoor air quality." Indoor Air, 8(2): 80-90.
 
Milton, D., P. Glencross, and M. Walters
2000. "Risk of Sick Leave Associated with Outdoor Air Supply Rate, Humidification, and Occupant Complaints." Indoor Air; 10(4):212-221. (Online version)
 
Mudarri, D.
1997. "Evaluating building IAQ and ventilation with indoor carbon dioxide." ASHRAE Transactions 103(2):193-204.
 
Orme, M.
1998. Energy impact of ventilation, Technical Note 49, International Energy Agency - Air Infiltration and Ventilation Centre, Coventry, Great Britain.
 
Persily, A.
1997. "Potential correction factors for interpreting CO2 measurements in buildings." ASHRAE Transactions, 103(2): 244-255
 
Persily, A. and W.S. Dols
1990. "The relation of CO2 concentration to office building ventilation." ASTM Special Technical Publication 1067-1990, pp. 77-91, American Society for Testing and Materials, West Conshohocken, PA.
 
Sandberg, M. and M. Sjoberg
1983. "The Use of Moments for Assessing Air Quality in Ventilated Rooms." Building and Environment 18, pp. 181-197.
 
Seppänen, O.
1999. "Ventilation strategies for good indoor air quality and energy efficiency." Proceedings of IAQ & Energy 98, American Society of Heating, Refrigerating and Air Conditioning Engineers, Atlanta. pp. 257-276.
 
Wargocki, P., D.P. Wyon, J. Sundell, G. Clausen and P.O. Fanger
2000 - The Effects of Outdoor Air Supply Rate in an Office on Perceived Air Quality, Sick Building Syndrome (SBS) Symptoms and Productivity. Indoor Air, 10(4): 222-236 (Online Version)
 
Centrifugal symbol Home | Research | Publications | References | Staff | Links
Indoor Environment Department | EETD | LBNL | Webmaster | Content Master
Centrifugal symbol